Description
SPECIFICATION OF INDUSTRIAL MULTIPLE PLC TRAINER:
Industrial Multiple PLC Trainer contain nine different reputed PLC where any two PLC does not use same, it has
used seventeen extra input and output modules for interfacing Nine different categories PLC. That’s
why students can be programming, interfacing with input and output load from nine
different reputed categories PLC. As a result they are capable to control of machinery from
industries where use of PLC.
LIST OF EXPERIMENTS:
The construction of nine different categories
PLC.
Interfacing method of nine different categories
PLC.
Programming method of nine different
categories PLC.
Pick & Place using PLC & Pneumatic Air Suction
method.
Pick & Place using PLC & Pneumatic Gripper
method.
Water Pump Control using nine different
categories PLC.
Fire Indication System using nine different
categories PLC.
Traffic Light Control using nine different
categories PLC.
The construction of Pneumatic cylinder.
Sequential control of three Pneumatic cylinder
using nine different categories PLC
The construction of Pneumatic solenoid valve.
Control of Pneumatic solenoid valve using PLC.
Interfacing of PLC & Pneumatic solenoid valve.
The method of Control Relay using PLC.
The methods of three phase Induction Motor
Starter using PLC.
Forward-and-reverse operation methods of three
phase Induction Motor.
The method of interfacing PLC with Input Switch.
Forward-and-reverse operation methods of three
phase Induction Motor.
The method of interfacing PLC with Input Switch.
The method of interfacing PLC with Input Sensor.
Operating method of interfacing proximity sensor
with PLC.
Operating method of interfacing photo sensor with
PLC.
Use of Variable Frequency Drive with PLC.
Programming method of Variable Frequency Drive
with PLC.
The construction of Three Phase Induction motor.
Interfacing Method of Three Phase Induction motor
with VFD & PLC.
The construction of Stepper Motor.
Interfacing Method of Stepper Motor with PLC.
The construction Seven Segment Display.
Interfacing Method of Seven Segment Display with
PLC.
Interfacing Power Supply with nine different
categories PLC.
Technical Specifications:
Main Structure:
– Main Voltage : 1 Phase 220V per 50 or 60Hz
– Working Table: 1EA
– Working Frame – 3 Step
– Module Storage Cabinet : 2EA
– Electric accessories Storage Cabinet : 1EA
– Air Compressor : 1EA
– Air compressor (basic equipment minimal
machine): power: AC 220V(Plus or Minus)10
percent 50Hz or 60Hz,motor power: 650W
– Nominal volume Air compressor: 9L
normal output Pressure 0.7 MPa, noise
degree: 66 dB
– Dimension :L x W x H (mm):1735 x700 x
1660
– Connection facility 2mm & 4mm Safety
Socket
PLC Category
PLC: SIEMENS
– Part Number: 6ED1052-1MD00-0BA8/1
– Programming Language: Ladder, Functional
Flow Chart Diagram
– Built in Ethernet communication
– PLC Power supply: (1 No.)
– PLC Digital Input: 08
– PLC Analog Input: 04 Nos
– PLC Analog Output: 02 Nos
– PLC Digital output: 04
– PLC Display Unit : YES
– PLC Input Voltage: 24VDC, 1Amp
– Permissible range, Lower limit(DC): 20.4V
– Permissible range, Upper limit(DC): 28.8V
– Programming Software: LOGO Soft Comfort or
equivalent
– Programming Cable: PLC to PC communication
Cable
– Connection facility 2mm & 4mm Safety Socket
– Module Dimension :L x W x H (mm):295 x 225 x
45
PLC: Schneider Electric
Parts: SR3B101BD or AFPX-C40R
Built in display: LCD
High-speed Operation
Number or control scheme lines
Maximum Number of I & O Points:
0…500 with FBD programming
0…240 with ladder programming.
Cycle time: 6…90 ms
Backup time: 10 years at 25 degree C
Checks: Program memory on each power up
Supply voltage limits: 19.2…30 V
Discrete input voltage: 24 V DC
Discrete input current: 4 mA
IP degree of protection: IP20 (terminal block)
conforming to IEC 60529
Mechanical durability: 10000000 cycles (relay
output)